Program 14-5 Overview - Toshiba Strata DK40 Programming Manual

Hide thumbs Also See for Strata DK40:
Table of Contents

Advertisement

Automatic Call Distribution

Program 14-5 Overview

There are two basic options for call overflow:
Overflow Point: Calls in queue can overflow when they reach a particular point in the queue
pattern (after the first, second, or third music timer expires). DATA = 1, 2, or 3 sets the music
timer overflow point.
Queue Timer Expiration: Calls can cycle in the queue pattern and the same
announcement(s) and music repeats until the overall queue timer (Program 11-1) expires (no
overflow point). DATA = 0 selects the queue timer expiration.
also see Flowcharts 6-2 and 6-8).
Calls in the queue can overflow when they reach a particular point (OP1, 2 & 3) in the queue
pattern,
If the timer set in Program 11-1 is reached before the overflow point (Program 14-5) the calls
will follow the overflow point set in Program 14-4.
Alternatively, if the calls are to remain in the queue, OP0 must be set and if applicable the
music/announcements will repeatedly be played to the caller until a free Agent becomes
available or the timer (Program 11-1) expires.
For further details,
Unavailable and the LED 04 is turned ON in Program 10-4, calls route to the destination set
in
Program
If the overflow destination is set to 320 or 321 calls overflow to the following destinations:
If announcements should not be repeated,
Queue Announcement" explanation under
CAUTION!
6-32
Program 14-5 Overflow Point and Ring No Answer Routing Destination
(see diagram later in this
see Program 14-3, Code 5 or see Flowcharts 6-4 and 6-8.
14-5.
If the overflow station(s) or [DNs] are busy when overflow time occurs, the
following options are available:
If the call(s) should exit the ACD queue and mute ring the busy overflow station,
assign Code 321 (normal ringing) in
the overflow station [DN] in
not apply to
Program 14-5
If the overflow destination is the Strata DK40 System built-in AA, calls will always
exit queue when the overflow point is reached – even if the AA is busy.
If the call(s) should remain in queue until the busy overflow destination becomes
idle assign the overflow destination as a [DN] (000~027) or ACD Group (01~08) in
Program 14-5.
Exchange lines - to the DK AA (320) or normal ringing patterns (321),
84 and 87.
Tie Lines - To the assignment set in
DDI Lines - To normal ringing patterns
When assigning the ring no answer destination for an ACD group, extreme
care must be taken as an ACD call will never revert back to where it started ringing.
(i.e. the ACD Gp 01 ring no answer destination cannot be to 301 (i.e. back to itself)).
Equally if ACD group 01's ring no answer destination is set to ACD group 02
(whose ring no answer has been set to 301) the call will not be able to follow ACD
Gp o2's ring no answer destination as this was where the call originated from.
section).
Program 14-5
Programs 81, 84 and
for delay ring.
Program
*14-2.
(Program
see Flowcharts 6-8~6-10
Program
14-5.
Strata DK40 Programming Manual Spring 1999
(See Program 14-3, Code 5,
If all Agents are
and assign the ACD lines to ring
87. Delay Ring assignments do
Programs 81,
81).
and "Non-Repeating

Hide quick links:

Advertisement

Table of Contents
loading