Test SMS
To check the selected settings and the connection, you can have the CMR send a test SMS
message to a configured recipient module.
● Recipient group
User group that is to receive the test SMS message.
● Text
Configured text that will be sent in the test SMS message.
● Send test SMS
The button triggers the sending of the test SMS with selected text block (previously
configured in "Message texts").
5.10.5

SMS alias

SMS alias configuration
In the table configure up to 20 values for the alias texts of SMS that the CMR is to receive.
These are SMS messages with writing access or SMS messages with a read command, for
example "DIAG?" to request a diagnostics SMS message.
You configure symbolic names as placeholders for the entire SMS text.
● Name
Symbolic name of the text
● Content
Suitable text of the alias SMS message with the correct syntax.
Example:
● The alias name is as follows: Lamp3ON
(This text will be transferred as the SMS message text.)
● The configured content is <password>;LOGO=VM125,1,WORD
(The variable VM125 of the type WORD is linked to the output for Lamp 3.)
When it receives an SMS message with the text "Lamp3ON", the CMR first checks the
configured password.
Then according to the configuration in the table the CMR translates remaining text in
"LOGO=VM125,1,WORD" and sets the variable VM125 of the type WORD to 1.
5.10.6

E-mail

In this tab you can configure the data for the sending of e-mails by the CMR.
LOGO! CMR2020,
LOGO! CMR2040
Operating Instructions, 10/2016, C79000-G8976-C356-03
Configuration (WBM)
5.10 WAN
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logo! cmr2020Simatic net logo! cmr2020Simatic net logo! cmr20406gk7 142-7bx00-0ax06gk7 142-7ex00-0ax0

Table of Contents