Configuration of the Ethernet interface
Note
IP address and subnet mask according to RFC 1918
The factory-set IP addresses and subnet masks can be changed as required, but must keep
to the specification RFC 1918. The CMR does not run any strict checks of the address
bands.
Do not set an IP address that is already assigned in your LAN, for example for other BMs.
If a duplicate IP address is detected, the red error LED starts to flash. The CMR is no longer
reachable via the Ethernet interface. No other functions are affected: e.g. sending an SMS
message due to events.
Fixed parameters
● MAC address
● Connection status
● Transmission properties (options: 10/100 Mbps; half/full duplex)
● Connected since (dd:hh:mm:ss)
Changeable parameters
● IP address
● Subnet mask
● Default router
The default router is intended for direct connection of the CMR to the Internet via the LAN
interface.
5.10

WAN

5.10.1

Overview

Mobile wireless connection
The following information on the mobile wireless interface is displayed in the Overview:
● Connection established
Connection status to the mobile wireless network
● Connected since (dd:hh:mm:ss)
Duration of the existing mobile wireless connection
LOGO! CMR2020,
LOGO! CMR2040