3.3.36

TMGL8 (for U.S. only)

Introduction
The TMGL8 trunk module connects up to eight analog ground-start or loop-start trunks to Hi-
Path 3750 and HiPath 3700.
Ground start is the default.
Switches and LEDs
Switches
Figure 3-116
TMGL8 (for U.S. only) (S30810-K2703-Z)
Switches
The TMGL8 board has an eight-path microswitch under a flip-up cover. The following settings
apply for each channel:
ON (right): Channel is enabled.
OFF (left): Channel is disabled; no new seizures are permitted.
3-288
1
On
8
H1
LEDs
.
.
.
.
H8