12.3.1.7

Eventlog for HiPath 3000

HiPath 3000 features an eventlog where accrued errors are classified according to error class
and error number with the date/time of the original error. You can use HiPath 3000 Manager E
to read out the eventlog.
Section 12.3.2 contains information on the possible entries.
12.3.1.8

Testing Telephones

After startup and country adaptation, you can activate the terminal test on any optiPoint 500 or
optiset E telephone using a code or the service menu. This test checks the display (your num-
ber is displayed), LEDs, and ring tones. The tests ends automatically after a period of time.
The test allows you to perform a visual and acoustic check of the components to ensure that
they are functioning properly.
Test procedure on the system telephone
Table 12-6
Terminal Test
Step
1.
2.
If the test does not react as described, an additional power supply (plug-in power
>
supply unit) for the relevant system telephone may be necessary.
If the time and date do not appear in the display after startup, either the system telephone or
the cable path is defective. Either exchange the system telephone or check the cable path.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
Entry
*940
Code for terminal test
For approximately five seconds, all LEDs blink quickly (ex-
cept for the Service menu LED), all display pixels are acti-
vated, and you can hear a tone.