Samsung iDCS 500 Programming Manual page 414

Hide thumbs Also See for iDCS 500:
Table of Contents

Advertisement

iDCS 500
TECHNICAL MANUAL
ALM
ALARM
CODE
MJD17
RAM Error
MJD18
E1 Restart
MJD19
PRI Restart
MJD20
BRI Restart
MJD21
PCM Loss
MJD22
PCM Recovery
MNF01
Card Out
MNF02
Card In
MNF03
IPC Error
MNF04
Trunk Fault
MNF05
Trunk Recovery
MNF06
Trunk Disconnect
MNF07
Trunk Connect
MNF08
SIO TxQ
MMC: 851
DEFINITION
An error has occurred in the TEPRI or BRI card RAM.
Alarm data = Cabinet, Slot (Cx-Syy)
The E1 card has restarted.
Alarm data = Cabinet, Slot (Cx-Syy)
The PRI card has restarted.
Alarm data = Cabinet, Slot (Cx-Syy)
The BRI card has restarted.
Alarm data = Cabinet, Slot (Cx-Syy)
Loss of PCM coding on a digital facility.
Alarm data = Cabinet, Slot (Cx-Syy)
Recovery of PCM coding on a digital facility.
Alarm data = Cabinet, Slot (Cx-Syy)
A circuit card mounted in a universal slot has been removed
from service or is not recognized by the system.
Alarm data = Cabinet, Slot (Cx-Syy)
A circuit card mounted in a universal slot has been removed
from service.
Alarm data = Cabinet, Slot (Cx-Syy)
Inter processor communication error has occurred.
Alarm data = Cabinet, Slot (Cx-Syy)
Out of service trunk detected via loop detect. Internal CODEC
test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Out of service trunk detected via loop detected as out of service
is now operational.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Out of service trunk detected via seizure of trunk. External
seizure test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Out of service trunk recovered via seizure of trunk External
seizure test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
SIO Tx Queue full error has occurred in the MCP.
Alarm data = SIO number (SIO:x)