Hydraulic Flow Diagrams: Standard Hydraulic Controls

REAR OPTION CIRCUIT (TWIN SPINNER SHOWN)
FLOOR CIRCUIT
Hydraulic System
FLOOR
SOLENOID
VALVE
FLOOR
CF
CONTROL
VALVE
IN
FLOOR
EX
MOTOR
HYDRAULIC
POWER PACK
FLOOR
SOLENOID
VALVE
FLOOR
CF
CONTROL
VALVE
IN
FLOOR
EX
MOTOR
HYDRAULIC
POWER PACK
Page 3 - - 14
OPTION
SOLENOID
VALVE
OPTION
EX
CONTROL
VALVE
IN
SPINNER
CF
MOTORS
Option solenoid valve is energized.
Excess and return flow will be routed
to hydraulic reservoir.
OPTION
SOLENOID
VALVE
OPTION
EX
CONTROL
VALVE
IN
SPINNER
CF
MOTORS
Both floor solenoid valve and option
solenoid valve are energized.
Excess and return flow will be routed
to hydraulic reservoir.
Working Pressure
Return
Flow