GE DVSR xU User Manual page 95

Table of Contents

Advertisement

DVSR xU User Manual
Sub information types. There are several different types of sub information depending on the
main type selected. See Table 24.
Table 24: Sub information types by main type
Main information types
All
Alarm
Notification
Operation
Date and time. Logs can be searched by date as well as start and end recording times.
1. In the System menu select the View Log edit box and press Enter or left-click the mouse. The View
Log menu appears. See Figure 65.
Figure 65: The View Log menu
2. To view the default log options
In the View log menu press Enter or left-click the mouse. The results are shown in the window
underneath.
3. To setup the search by type
a. In the View Log menu go to the Search by list box and select one of the four options: All,
Category & Time, Time, and Category.
Sub information types
All
All, ViewTamper Stop,ViewTamper Start, MotDetStop, MotDetStart, Alarm Out,
Alarm In
All, DCDLost, IP Conflict, HardDiskFull, HardDiskError, IllegalAccess
All, SaveToSATADISK, EndSaveToSATADISK, EndSaveToIDECDRW,
EndSaveToUSBCDRW, EndSaveToUSBHD, EndSaveToUSBDISKK, change,
Altered, File End Time, File Start Time, Net PTZ, Net Time Play, Net File Play,
Net Upgrade, BiComStop, BiComStart, Net Reboot, Alert Off, Alert On,
NetGetStatus, NetGetConfig, NetGetPara, NetStopTrans, NetStartTrans,
NetStopRecord, NetLogout, NetLogin, LocalFileCopy, LocalUpgrade,
Panel Set Time, PanelPTZ, LocalStopRec, LocalStartRec, PanelTimePaly,
PanelConfig, PanelLogout, PanelLogin, AbnormalShut, Shutdown, PowerOn
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents