Table 3. Field And Parameter Descriptions - Continued - Motorola A920 Service Manual

Hide thumbs Also See for A920:
Table of Contents

Advertisement

Handset Test Commands

Table 3. Field and Parameter descriptions - continued

Opcode
Opcode
(Decimal)
Mnemonic
57
VERSION
62
LEDS
3083
WLOAD_SYN
2 - 10
Field Description
Field 1
016000 = DSP Version
017000 = User (login) pf process that created this file
017001 = Build time (universal) in ISO-8601 format
017002 = Clearcase view tag name
017003 = Product base label from Clearcase config spec
017004 = Product ID
017005 = Version Number
017006 = Build commentary
018000 = Flash Booter version number (P2K Booter Only)
Field 1 0 = Keypad Backlight LED
3 = Red LED
4 = Green LED
Field 2 3 = Set duty cycle (Red/Green LEDS Only)
Field 3 Duty Cycle setup,
000 = Off
012 = ON
Field 1 UARFCN for Receive Frequency ID. Valid values are
between 0 and 16383. If TX_FREQ_ID is set to 0xFFFF,
then RX_FREQ_ID must take values between 190*5 and
16383.
Note : If a valid TX_FREQ_ID will be entered,
RX_FREQ_ID must be set to FFFF.
Field 2 UARFCN for Transmit Frequency ID. Valid values are
between 0 and 16383. If it is set to 0xFFFF the TEST_TASK
will derive the TX_FREQ_ID from the RX_FREQ_ID.
Note : If a valid RX_FREQ_ID is entered, TX_FREQ_ID
must be set to FFFF.
Motorola Confidential Proprietary