Firmware Server Setup - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

7.2 Firmware Server Setup

No special server is necessary for the firmware update. You can use an HTTP, HTTPS, FTP, or TFTP server
as the firmware server by simply setting its URL.
7.3 Firmware Update Settings
Firmware updates are provided by the manufacturer when necessary.
The firmware update will be executed by setting the corresponding parameters using configuration file
programming (® see 4.2.4 Firmware Update Settings) or Web user interface programming (® see
2.7.3 Firmware Maintenance).
Note
After firmware updates are complete for the SIP-CSs, the newer firmware will be applied to the S-PSs.
If the firmware version of an S-PS is older, the firmware updates for the S-PS will be executed to register
to the SIP-CS.
If you are using a language other than English, the display language may unexpectedly change to
English during an S-PS firmware update. One of the following messages may be displayed:
Displayed Message
<ERASING>
<WRITING>
<WRITE OK>
<ERROR 1>
<ERROR 2>
<Charge Battery>
When executing firmware updates for the S-PSs, make sure of the following:
The target S-PSs are on the charger with the power ON.
The S-PSs' batteries have enough charge remaining (
The S-PSs are located where the radio signal is strong (
The S-PSs are in standby mode.
If automatic update is enabled and the S-PS firmware update does not start automatically after the
SIP-CS firmware update, turn the S-PS off and on.
The following shows the parameters and the setting procedures:
Firmware Update Enable/Disable
In a configuration file, add the line, FIRM_UPGRADE_ENABLE="Y".
In the Web user interface, click the [Maintenance] tab, click [Firmware Maintenance], and then select
[Yes] for [Enable Firmware Update].
Firmware Version Number
In a configuration file, specify the new version number in "FIRM_VERSION".
Automatic Update
In a configuration file, add the line, PS_FIRM_UPGRADE_AUTO="Y".
Document Version 2013-03
Description
Data is being erased.
Data is being written.
Data writing was successful.
A deletion error occurred.
A writing error occurred.
Charge the S-PS's battery.
7.3 Firmware Update Settings
or
is recommended).
or
is recommended).
Administrator Guide
267

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents