7.2 Firmware Server Setup
No special server is necessary for the firmware update. You can use an HTTP, HTTPS, FTP, or TFTP server
as the firmware server by simply setting its URL.
7.3 Firmware Update Settings
Firmware updates are provided by the manufacturer when necessary.
The firmware update will be executed by setting the corresponding parameters using configuration file
programming (® see 4.2.4 Firmware Update Settings) or Web user interface programming (® see
2.7.3 Firmware Maintenance).
Note
•
After firmware updates are complete for the SIP-CSs, the newer firmware will be applied to the S-PSs.
•
If the firmware version of an S-PS is older, the firmware updates for the S-PS will be executed to register
to the SIP-CS.
•
If you are using a language other than English, the display language may unexpectedly change to
English during an S-PS firmware update. One of the following messages may be displayed:
Displayed Message
<ERASING>
<WRITING>
<WRITE OK>
<ERROR 1>
<ERROR 2>
<Charge Battery>
•
When executing firmware updates for the S-PSs, make sure of the following:
–
The target S-PSs are on the charger with the power ON.
–
The S-PSs' batteries have enough charge remaining (
–
The S-PSs are located where the radio signal is strong (
–
The S-PSs are in standby mode.
•
If automatic update is enabled and the S-PS firmware update does not start automatically after the
SIP-CS firmware update, turn the S-PS off and on.
The following shows the parameters and the setting procedures:
Firmware Update Enable/Disable
•
In a configuration file, add the line, FIRM_UPGRADE_ENABLE="Y".
•
In the Web user interface, click the [Maintenance] tab, click [Firmware Maintenance], and then select
[Yes] for [Enable Firmware Update].
Firmware Version Number
•
In a configuration file, specify the new version number in "FIRM_VERSION".
Automatic Update
•
In a configuration file, add the line, PS_FIRM_UPGRADE_AUTO="Y".
Document Version 2013-03