4.2.5 Provisioning Settings
Value Range
Default Value
CFG_PRODUCT_FILE_PATH
Value Format
Description
178
Administrator Guide
Max. 500 characters
Note
•
The format must be RFC 1738 compliant, as follows:
"<scheme>://<user>:<password>@<host>:<port>/<url-path>"
–
"<user>" must be less than 128 characters.
–
"<password>" must be less than 128 characters.
–
"<user>:<password>@" may be empty.
–
The total of "<scheme>://" and "<host>:<port>/<url-path>"
must be less than 245 characters.
–
":<port>" can be omitted if you do not need to specify the
port number.
•
If "{mac}" is included in this URL, it will be replaced with the
SIP-CS's MAC address in lower-case.
•
If "{MAC}" is included in this URL, it will be replaced with the
SIP-CS's MAC address in upper-case.
•
If "{MODEL}" is included in this URL, it will be replaced with the
SIP-CS's model name.
•
If "{fwver}" is included in this URL, it will be replaced with the
SIP-CS's firmware version.
•
If this URL ends with "/" (slash), "Config{mac}.cfg" is
automatically added at the end of the URL.
For example, CFG_STANDARD_FILE_PATH="http://
host/dir/" becomes
CFG_STANDARD_FILE_PATH="http://host/dir/
Config{mac}.cfg".
http://provisioning.e-connecting.net/redirect/conf/{mac}.cfg
String
Specifies the URL of the product configuration file, which is used when
all SIP-CSs with the same model number need the same settings.
Note
•
When you change this setting, set "PROVISION_ENABLE" to
"Y" at the same time.
Document Version 2013-03