a131
Acceleration curve constant
a132
Deceleration curve constant
A141
A input select for calculate
function
A142
B input select for calculate
function
A143
Calculation symbol
A145
ADD frequency
A146
ADD direction select
a150
Curvature of EL-S-curve at the
start of acceleration
a151
Curvature of EL-S-curve at the
end of acceleration
a152
Curvature of EL-S-curve at the
start of deceleration
a153
Curvature of EL-S-curve at the
end of deceleration
a154
Deceleration hold frequency
a155
Deceleration hold time
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
"A" Function
Description
Range is 01 to 10.
Range is 01 to 10.
Seven options:
00...Operator
01...VR
02...Terminal [O] input
03...Terminal [OI] input
04...RS485
05...Option
07...Pulse train input
Seven options:
00...Operator
01...VR
02...Terminal [O] input
03...Terminal [OI] input
04...RS485
05...Option
07...Pulse train input
Calculates a value based on the
A input source (A141 selects) and
B input source (A142 selects).
Three options:
00...ADD (A input + B input)
01...SUB (A input - B input)
02...MUL (A input * B input)
An offset value that is applied to
the output frequency when the
[ADD] terminal is ON.
Range is 0.0 to 400.0 Hz
Two options:
00...Plus (adds A145 value to the
output frequency setting)
01...Minus (subtracts A145 value
from the output frequency
setting)
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
Sets the frequency to hold
deceleration, range is 0.0 to
400.0Hz
Sets the duration of deceleration
hold, range is 0.0 to 60.0
seconds
56
Run
Defaults
Mode
Lnitial data
Units
Edit
02
02
02
03
00
0.00
Hz
00
10.
%
10.
%
10.
%
10.
%
0.0
Hz
0.0
sec.