Maximum number of alarm transmitters

This command sets the maximum number of alarm transmitters (300=OFF or 500=ON).
The default value is ON (500).
4.4.10

Maximum number of acknowledgement transmitters

This command sets the maximum number of acknowledgement transmitters (5=OFF or
32=ON). The default value is OFF (5).
4.4.11

Maximum number of events buffered

This command sets the maximum number of events buffered (18=OFF or 100=ON). The
default value is ON (100).
CAUTION!
When changing the value with this command, the event buffer is erased.
4.4.12

Disabling the daily messages check

Periodically, a message is sent by each transmitter in order to confirm its good functioning
condition. To avoid saturating the event buffer, you can disable the daily message check
performed by the NurseCall Main Unit by using this command and setting the parameter ON.
Activate (ON) or deactivate (OFF) the disabling of the daily message check.
The default value is OFF (daily message check enabled).
4.4.13

RS232 message setting

This command sets the delay in minutes for the repetition of the messages on the RS-232
interface. Toggle "every 3 minutes" (OFF) or "every 1 minute" (ON). The default value is OFF.
Bosch Security Systems
Type the code 001001. A confirmation message is displayed.
Type the code 001002. A confirmation message is displayed.
Type the code 001003. A confirmation message is displayed.
Type the code 001007. A confirmation message is displayed.
Type the code 001009. A confirmation message is displayed.
User Manual
Programming | en
37
F.01U.252.699 | V1.1 | 2012.01