Special Installation (Place product upright and flush into wall (embedding in the wall))

3.6.7 Place product upright and flush into wall (embedding in the wall)

Carefully read the following before trying to embed the unit in a wall, and make sure to observe all the limitations
specified below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (with no obstructions within a distance of 300mm
from the back surface of the unit).
A
A
<Viewed from the Right Side>
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
Before attaching the unit to fittings, double-check that the thickness and height of the fittings,
and the number of fixing bolts is correct.
(Also refer to 3.6.1 "Mounting to fittings".)
64
A
X (Front of the unit)
Y (Rear of the unit)
<Viewed from Above>
✩ Operating Temperature Restrictions
A: 0 to 370 mm
. The methods indicated by a large X-mark must not be used.
[433CMX/433MXE]
A
Temperature in space X and Y
0 to 40 °C