Special installation (Wall embedding (vertically wall-embedding equipment))

3.4.11 Wall embedding (vertically wall-embedding equipment)

This display is designed to accommodate embedding in a wall. Since the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following conditions:
1 If the unit must be embedded in the wall, the side slots of the unit must not be blocked. Avoid blocking the
ventilating holes in the rear as much as possible.
2 Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
3 Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
4 Installation conditions and ambient operating temperatures:
(1) If the space behind the wall is open
B
C
100
100
mm
mm
X
MAX. 20 mm
(for both top
and bottom)
C
B
46
<Ver. 2.1>
Side slits
A
A
B
Exhaust
Install the display with
the fan on top.
Y
A ≥ 100 mm, B ≤ 150 mm
A ≥ 100 mm, B ≥ 150 mm
A ≤ 100 mm, B ≤ 80 mm
A ≤ 100 mm, B ≥ 80 mm
Take C to be 30 mm or more.
A
Never block the side slots. Avoid
blocking the ventilating holes of the
rear of the unit as much as possible.
Caution
X
Y
X, Y space upper temperature limits
35 °C
35 °C (Animation), 30 °C (Still)
35 °C
30 °C
A
B