E66: Heating Element Power Supply Relay Faulty - Electrolux 6 Series Service Manual

Hide thumbs Also See for 6 Series:
Table of Contents

Advertisement

Guide to diagnostics of NEW COLLECTION EWM09312 electronic controls
E66
Measure between the connector J6-1/J6-2 of
the main circuit board and the appliance body.
(fig. 6) Is there any dispersion?
Detach the connector J6 and measure between
the heating element and the earth contact.
(fig. 15) Is the circuit open?
Check/replace the wiring and repeat the
diagnostic cycle to check for any further alarms.
J5
J11
J14
J4
GND
Fig.4
If there are burns on the circuit board,
!
see page 59
T.S.-mdm FCPD-dp Quality tb

E66: Heating element power supply relay faulty

YES
YES
J13
J10
J8
J7
J6
General earthing
connection
Washing heating
element
!
Check that all the connectors are correctly inserted
Replace the circuit board and repeat
the diagnostic cycle to check for any
NO
Replace the heating element and repeat
the diagnostic cycle to check for any
NO
fig. 6
44/61
further alarms.
further alarms.
Fig. 15
MAIN CIRCUIT
BOARD
599 74 42-27 Rev.00
E66