5.3

Alarm Summary Table

Alarm
Description
E00
E11
Water fill difficulty during washing
E13
Water leaks
E21
Drain difficulty during washing
E23
Faulty triac for drain pump
Malfunction in sensing circuit on
E24
triac for drain pump
Malfunction in electronic pressure
E31
switch circuit
Calibration error of the electronic
E32
pressure switch
E35
Overflow
Internal pressure chamber is
clogged (water level does not
E38
change for at least 30 sec. of
drum rotation)
E41
Door open
E42
Problems with door lock
Faulty triac supplying power
E43
to door delay system
Faulty sensing by door
E44
delay system
Faulty sensing by door
E45
delay system triac
T.S.-mdm FCPD-dp Quality tb
Guide to diagnostics of NEW COLLECTION EWM09312 electronic controls
Possible fault
Tap closed or water pressure too low; Drain pipe improperly positioned;
Water fill solenoid valve faulty; Leaks from water circuit on pressure
switch; Pressure switch faulty; Wiring faulty; Main PCB faulty.
Drain pipe improperly positioned; Water pressure too low;
Water fill solenoid valve faulty; Water circuit on pressure switch is
leaking/clogged; Pressure switch faulty.
Drain pipe kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Wiring faulty; Pressure switch faulty; Drain pump rotor
blocked; Drain pump faulty; Main PCB faulty.
Wiring faulty; Drain pump faulty; Main PCB faulty.
Main circuit board faulty.
Wiring; Electronic pressure switch; Main PCB;
Drain pipe kinked/clogged/improperly positioned; Solenoid valve faulty;
Drain filter clogged/dirty; Drain pump faulty; Leaks from pressure switch
hydraulic circuit; Pressure switch faulty;
Wiring; main PCB;
Water fill solenoid valve faulty; Leaks from water circuit on pressure
switch; Wiring faulty; Pressure switch faulty; Main PCB faulty.
Motor belt broken; Water circuit on pressure switch clogged.
Check whether the door is closed properly;
Wiring faulty; Door safety interlock faulty;
Main circuit board faulty.
Wiring faulty; Door safety interlock faulty;
Electrical current leak between heating element and ground;
Main PCB faulty.
Wiring faulty; Door safety interlock faulty;
Main circuit board faulty.
Main circuit board faulty.
Main circuit board faulty.
Cycle is paused with door locked
Cycle is paused with door locked
Safety drain cycle - Cycle stops with
door open
Safety drain cycle - Cycle stops with
door unlocked
Cycle stops with door locked
Cycle interrupted. Safety drain cycle.
Drain pump continues to operate
(5 min. on, then 5 min. off. etc.)
Heating phase is skipped
13/61
Machine status/action
Reset
START/RESET
START/RESET
START
Cycle paused
ON/OFF
(after 2 attempts)
RESET
RESET
RESET
RESET
Cycle paused
START/RESET
RESET
RESET
Cycle paused
START/RESET
Cycle paused
START/RESET
(Safety drain cycle)
RESET
Cycle blocked
(Safety drain cycle)
RESET
Cycle blocked
(Safety drain cycle)
RESET
Cycle blocked