5.4 Notes on the behaviour of certain alarms

Configuration alarm E93: when this alarm is detected (on switching on the appliance), the appliance stops, the display shows the alarm code provided the
relevant configuration part is intact.
It will not be possible to access diagnostics mode and the only available option is to turn the appliance off.
Configuration alarm E94: The code is also shown on the display.
The diagnostics mode cannot be accessed and the "quick alarm viewing" mode cannot be used.
Alarms EH1-EH2-EH3: in the event of problems with the supply voltage, the appliance remains in alarm status until the mains frequency or voltage returns to
acceptable values or the appliance is switched off (programme selector set to "0"). Only the family of the alarm "H".
Alarms E51- E52: all the alarms are displayed during diagnostic testing: normally, when shifting from one control phase to another, the appliance quits the
alarm mode and executes the selected phase. This is not the case for alarms E51 (motor power supply TRIAC short-circuiting) and E52 (no signal from motor
tachometric generator): the only choice to quit the alarm mode is to turn off and on the appliance wit ON/OFF button.
T.S.-mdm FCPD-dp Quality tb
Guide to diagnostics of NEW COLLECTION EWM09312 electronic controls
16/61
599 74 42-27 Rev.00