Panasonic GP-X Series User Manual page 137

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

Application Mode Setting
To designate the application mode using RS-232C commands, set each
mode, followed by the necessary items.
1) Bottom dead center detection mode
2) Rotation/eccentricity detection mode
3) Height detection mode
Ramco Innovations www.ramcoi.com
Select the BDC detection mode.
Transmission: %EE#WAP01
Response: %EE$WAP0
Set the trigger level (WTT).
Set the level at "0.8000".
Transmission: %EE#WTT0+000.8000
Response: %EE$WTT0
Set the trigger hysteresis (WTH).
Set the hysteresis at "0.0020".
Transmission: %EE#WTH00000.0020
Response: %EE$WTH0
Comparison with previous mean (WPA) setting
Validate comparison with previous mean.
Transmission: %EE#WPA01
Response: %EE$WPA0
Selection of rotation/eccentricity detection mode
Transmission: %EE#WAP02
Response: %EE$WAP0
Trigger hysteresis setting
Set the trigger hysteresis at "0.0100mm".
Transmission: %EE#WTH00000.0100
Response: %EE$WTH0
Before starting the height detection mode, perform zero setting at the ref-
erence position.
Zero setting can be performed with an RS-232C command.
Selection of height detection mode
Transmission: %EE#WAP03
Response: %EE$WAP0
Value change inclination (slope) setting
Inclination of the variation in the displayed value and analog voltage
output is negative in the height detection mode. To change the inclina-
tion to positive, adjust the analog voltage scale.
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR