Command for adjustment
Item
Zero setting
Command for adjustment
Item
Scaling
Analog
voltage
output
118
Ramco Innovations www.ramcoi.com
Controller
Command
Instruction character
address
string (m)
Loading
Writing
(n) 1)
0:
Zero setting ON
WZS
0
1:
Zero setting OFF
Controller
Command
Instruction character
address
string (m)
Loading
Writing
(n) 1)
First point of
0:
two-point
scaling
1:
Second point
of two-point
scaling
RSV
0
2:
Setting of two
scaling points
3:
Scaling
selection data
4:
Output inverse
ON/OFF
Outline
Perform or cancel zero setting of the
controller of the designated address.
The response to
%
E
E # W Z S n m
is:
%
E
E $ W Z S n
C R
Outline
Load the current scaling data of the analog
voltage output.
The
detected
distance
corresponding analog voltage output are
sent back.
Load the data concerning scaling.
<Loading the setting of each scaling point>
%
E
E # R S V n m
m = 0 or 1
The response to the above command is:
%
E
E $ R S V n m :
& & & &
.
& & & &
+
& & &
Detected distance value
Analog voltage output value
C R
m = 0 or 1,
<Loading the setting of two scaling points (2 points batch)>
The response to
% E E # R S V n 2
is:
% E E $ R S V n 2
&
&
&
&
.
&
&
&
&
+
&
Detected distance value of 1st point Analog voltage output value of 1st point
&
&
&
&
.
&
&
&
&
+
Detected distance value of 2nd point Analog voltage output value of 2nd point
C R
The response to
% E E # R S V n 3
is:
% E E $ R S V n m
m=0: Factory shipment setting
m=1: One-point scaling
m=2: Two-point scaling
m=3: Inverse
The response to
% E E # R S V n 4
is:
% E E $ R S V n m
m=0: Inverse OFF
m=1: Inverse ON
Phone 800-280-6933 nsales@ramcoi.com
Setting
example
Example 7
C R
Setting
example
and
the
C R
.
& & & &
Space
C R
Example 8
&
&
.
&
&
&
&
&
&
&
.
&
&
&
&
Space
C R
C R
C R
C R