5.3.3 Calculation Between Controllers

of calculation.
Addition: A + B
Notice
Setting example
Controller Communication unit and Address Setting
(Value of controller 1) - (Value of controller 2) 
<Option>
<Calculation setting>
Press
The value displayed at this time is the calculated
value.
To make a judgment, enter the upper and lower limits
for the calculated value.
To check the detected value of the controller, press
the
key. The value is displayed on the upper line.
At address 2 controller, "
equation display, to indicate that data is sent to
address 1.
106
Ramco Innovations www.ramcoi.com
result of calculation is not output.
Press
to select "com".
Controller address 1
three times to return to the detection state.
" is displayed for
5.3.2 Connection of
If an address used for calculation of another
combination is designated, error "
displayed. If no controller is found at the address
designated for calculation, error "
displayed.
Check the connection of controller communi-
cation units (GP-XCOM) and specified address.
Press
to reset after the error and to return
to normal operation.
No calculation
Addition
Subtraction
Press
address selection.
Press
Set
Phone 800-280-6933 nsales@ramcoi.com
-
-
" is
" is
Press
to select
"sub" (subtraction).
to move to controller
to select "2".
Controller address 2