What's a SPID?
SPIDs are Service Profile Identifiers. SPIDs are used
to identify the ISDN device and allow a large
uniformity for setting the ISDN device with a switcher.
When the system connects to the following types of
network switcher, you can use ISDN lines and will
have to register the SPID.
«AT&T SESS
— Network switcher software: SE8 or later (for
National ISDN-1 and National ISDN-2)
e Northern Telecom (NT1) DMS-100
~ Network switcher software: BCS34 or later (for
National ISDN-1 and National ISDN-2)
About custom ISDN
The Vidio Transmitter can communicate with custom
ISDN. In such case, please use the following particular
country codes.
* AT&T SESS Multipoint custom
110
* AT&T SESS Point to Point custom
112
* Northern Telecom DMS-100 custom
111
Setting the Communication
Mode
When your country or region has a 56 Kbps line rate,
set the ISDN line rate.
When you connect via the V.35 interface, set the
number of channels and line rate.
1 Select 33. COMMUNICATION MODE from the
SETTING menu.
The following screen appears.
| ———COMMUNICATION
MODE—
IMODE;[BAK| 56K
U35 PORT [DUAL SINGLE
RATE: 11281K
123456
«CANCEL?
«40K»
2 When you connect the remote site via ISDN, select
the line rate for sending and receiving using 4 or
æ., then press Y.
64K: via normal ISDN line.
56K: specific regions or countries with a 56 Kbps
ISDN line rate.
3 When you connect the remote site via the V.35
interface, select the number of channels using € or
*. then press Y.
DUAL: when you use both the CHANNEL A
and B ports of the terminal adaptor.
SINGLE: when you use only the CHANNEL A
port of the terminal adaptor.
4 Select the line rate of the V.35 interface for
receiving using € or >, then press y.
* When you use both the CHANNEL A and B ports
of the terminal adaptor, set the line rate to 128 K.
* When you only use the CHANNEL A port of the
terminal adaptor, set the line rate between 64 and
384 K.
5 After entering the line rate, move the cursor to
«OK» using ¥, then press ENTER.
The setting is registered and the SETTING menu
appears.