7
.2.5
INTENSITY
CONTROL
The
INTENSITY LEVEL signal
from the front
panel
control
is
gated
with
the
SCOPE
Z-AXIS signal
hy the intensity-level
gate
(Q6). The gated
signal
is
summed
(U25)
with
the
HIGH
VOLTAGE REF
and
INTENSITY
SAMPLE
VOLTAGE
signals,
to
pro-
vide the
INTENSITY
TRACKING
VOLTAGE (TV)
signal.
T
he INTENSITY
TV
is
the
low-frequency
control
path
which
drives
the
intensity
opto-isolator
in
the High-Voltage Supply.
7.2.6
FOCUS CONTROL
The FOCUS TRACKING VOLTAGE
(TV)
signal
is
obtained
by
comparing
the FOCUS
LEVEL control
line to the
FOCUS
SAMPLE
VOLT
signal.
The
TV
signal
drives an opto-isolator circuit
in
t
he
High-Volt-
age
Supply which
controls
the
CRT focus voltage.
7-2
7.2.7 ASTIGMATISM,
GEOMETRY,
AND TRACE
ROTATION
The
CRT alignment
controls
fo
r
astigmatism
,
geometry and trace
rotation
are obtained
from
the
respective
wipers
of
three potentiometers
.
Each
potent
iometer
is
connected
between
supply voltages
eq ual to the required
adjustment range.