E 3-24
TEST 4: Strobe test
The display indicates
STRO
x
where x is a number from 6 to 15. This number changes continuously and slowly. By pressing the key
"MODULATION
OFF" at the right moment the required strobe line will be selected. The display shows
then e. g.:
STRO
@8 —
1
which means that the output lines of the shift registers controlled by strobe line 8 show a specific bit-
pattern.
ff MODULATION
OFF
was pressed once for a short moment
all output fines of the shift
registers change their state. Now the display shows:
STRO
08 — @
Each time the MODULATION
OFF-key is pressed for a short moment, the states of these output lines
will be inverted.
If MODULATION
OFF
is pressed for longer than about 1 second, this subprogram
will be left and the display shows again:
STRO
x
ASCII 'A'
indication 41 H
ASCII '3'
indication 33 H
etc.
The device address of the PM 5191 is fixed to 20.
With the key MODULATION