Modulation Mode AM (Amplitude Modulation)
This modulation mode is switched on by operating the key INT or EXT.
Modulation frequency and depth:
internal:
1 kHz fixed, modulation depth 30 % fixed
external:
0 Hz... 200 kHz, modulation depth depends on the amplitude of the modulation signal
Example: Amplitude Modulation (AM), internal
intended settings
key operations
wave form
sine
frequency (carrier)
:
25kHz
[2]
[= ]
*
amplitude
>
17V
Vpp
[a]
[- ]
offset voltage
:
O.5V
Vdc
[- ] [Ee |
modulation mode
:
internal
INT
modulation depth
30 % (fixed)
The modulation mode is switched off using key OFF.
e.g. Vde = 0.1 V instead 0.5 V
or frequency 100 kHz instead 25 kHz