Installation
Overview
Caution.
Note
9
HP 103140
The following procedure describes the major steps required to perform
measurements with the HP 10314D Preprocessor Interface. The page
numbers listed in the various steps refer you to sections in the manual
that offer more detailed information.
To prevent equipment damage, remove the power from both the logic
analyzer and the target system whenever the preprocessor interface or
microprocessor is being connected or disconnected.
1.
If
required, move jumpers
J5
through J8 to select between signals
for analysis. Then update the Format menu to match your
current selections (see "Jumpers" page 1-4).
To disable the HLDA line from stopping the logic analyzer clocks,
move jumper J9 to the ON position (see page 2-12).
2. Move the State/l'iming switch to the appropriate position for
state or
timing
analysis (see page 1-4).
3. Install the 80386DX preprocessor interface (HP 10314D) into the
HP 10269C Probe Interface (see page 1-6).
4. Connect the 80386DX microprocessor connector to the target
system (see page 1-8).
5. Plug the logic analyzer probes into the probe interface as listed in
table 1-1 on page 1-10. Note that the logic analyzers are grouped
into three categories. These same groupings apply to the
configuration files.
6. Load the logic analyzer configuration and inverse assembler for
the specified logic analyzer (see page 1-12). Table 1-2 lists the
configuration files and the inverse assemblers (see page 1-10).
7. For timing analysis, select the configuration menu of the logic
analyzer and select Timing as the analyzer "Type" (see page 2-15).
80386DX
Preprocessor Interface
Setting Up the HP 103140
1-3