ii) Setting the operation items
Setting Item
Mode
Start
Write
Write
Speed setting
(RAM)
Read
Write
Speed setting
2
(E
PROM)
Read
Speed
Read
Motor
Read
current
Output
Read
voltage
Alarm
Read
code
Drive unit
Read
status
Reset
Write
Alarm code
Write
batch-clear
Instruction
Data Codes and Definitions
Code
H00: Stop
H02: Forward rotation
H04: Reverse rotation
HFA
H0000 to H1C20: 1r/min increments
HED
(hexadecimal)
To change the running speed
H6D
consecutively, write to the drive unit RAM.
HEE
H0000 to H1C20: Unit 1r/min
H6E
(hexadecimal)
H6F
H0000 to H1C20: 0 to 7200r/min
H70
H0000 to HC350: 0 to 500.00A
H71
H0000 to H0FA0: 0 to 400.0V
H
Latest alarm
H74
Previous
alarm
H
Alarm two
times prior to
H75
Alarm three
times prior to
H
Alarm four
times prior to
H76
Alarm five
times prior to
H
Alarm six
H77
times prior to
Alarm seven
times prior to
H01: Function assigned to RUN terminal is
activated
H02: During forward rotation (STF terminal
signal ON)
H04: During reverse rotation (STR terminal
H7A
signal ON)
H40: Function assigned to FU terminal is
activated
H80: Alarm output is provided
H9696: The drive unit is reset.
In this case, the drive unit returning
data is not returned. After a reset,
HFD
wait for more than 100ms and send
the computer sending data.
H9696: Eight alarms stored as a history
HF4
are all cleared.
8-17
Get other manuals https://www.bkmanuals.com
8 PARAMETER FUNCTIONS
b7
b0
0
0
0
0
0
0
1
0
(For forward rotation)
H00: No alarm
H10: 0C1
H11: 0C2
H12: 0C3
H20: 0V1
H21: 0V2
H22: 0V3
H30: THT
H31: THM
H40: FIN
H51: UVT
H60: OLT
H70: BE
HB0: PE
HB1: PUE
HFF: E15
Character
count
2
4
4
4
4
4
4
4
4
4
2
4
8
4