Acceleration Time And Deceleration Time - Mitsubishi Electric MELIPM Series Instruction Manual

Magnetic motor drive unit
Table of Contents

Advertisement

8.5.2 Acceleration time and deceleration time

Pr. 7
"acceleration time"
Pr. 8
"deceleration time"
Pr. 20
"acceleration/deceleration reference speed"
Pr.
7, 8
20
In Pr. 7, set the time required to increase the speed from a start to the speed set
in Pr. 20.
In Pr. 8, set the time required to decrease the speed from the speed set in Pr. 20
to a stop.
Pr.20
The minimum value of acceleration/deceleration time is 0.5s. Any
acceleration/deceleration time setting of less than 0.5 is handled as
0.5s.
The upper limit of acceleration time at up to 500r/min is 20s
(conversion value up to rated speed). When the acceleration time
setting is greater than 20s, therefore, the acceleration time required
to reach the acceleration/deceleration reference speed is
represented by the following expression and is shorter than the
preset acceleration time:
Required acceleration time = 1.4 + T1
MEMO
T1 = (preset speed command - 500) × Pr. 7 setting
During deceleration, the motor will coast at less than 300r/min.
Therefore, the time required for deceleration from the speed set in
Pr. 20 to 300r/min is as follows:
Required deceleration time = Pr. 8 setting × (Pr. 20 setting - 300)
A too short acceleration/deceleration time setting can cause an
abnormal stop due to overload, overcurrent or overvoltage. Make a
setting which will not display overload on the parameter unit.
Setting Range
0.00 to 60.00
1 to 7200
Pr.7
/Pr. 20 setting
8-8
Get other manuals https://www.bkmanuals.com
8 PARAMETER FUNCTIONS
Unit
s
r/min
Running speed
Coasting
Time
Pr.8
/ Pr. 20 setting

Advertisement

Table of Contents
loading

Table of Contents