Note 1: If COUNT, RANGE, GRAPH or CUSTOM is selected, the display is shown below:
COUNT: displays the totalized flow counts (up to 8 digits).
RANGE: displays the range number being used for measurement (1 to 4).
GPARH: displays the measured value (% value) in bar graph.
In addition, the range number being used for measurement is also displayed.
CUSTOM: displays the result obtained by multiplying m
The details see 10.10 "Custom unit function".
Note 2: GRAPH display can be selected only for Display 2 screen.
Note 3: Mgl=1,000,000 gal.
Note 4: Please do the unit setting of the HART communication by the HART communication.
For display settings, Display 1 (DSPL1) and Display 2 (DSPL2) can be set independently.
The following is an example to change the Display 1 setting from % to mL/s.
Switch operation
B:DISPLAY
1 DSPL1
2 DSPL2
3 CS VAL
4 CS UNIT
5 EXIT
DSPL1
STEP1
%
DSPL1
STEP2
%
DSPL1
STEP3
mL/s
DSPL1
STEP4(=END)
mL/s
SET OK?
Note 1: The first unit (volumetric units etc.) changes as shown below:
3
%
m
L
GRAPH
Mgl
Display example
Select "DSPL1" from the setting item
selection menu.
ESC
The currently set display setting (% in this
example) appears.
Then push
* Pushing
menu.
ESC
The switches at the bottom change.
(
At the same time, the cursor appears.
Push
second unit to the third unit and change the
display unit by pushing
Repeat this operation to change the display
unit to mL/s.
When the desired display unit is selected,
push
temporarily.
Pushing
whether the setting is OK or not.
If OK, push
the setting, push
Pushing
operation and exits the setting screen.
ESC
O K
N O
mL
bbl
3
ft
CUSTOM
qt
− 61 −
6 F 8 A 0 9 2 7
3
/min by the custom coefficient.
Description
.
returns you to the setting
ESC
are shown.)
to move the cursor from the
to set the display unit
shows a message to confirm
O K
. If you need to redo
.
N O
ESC
cancels the setting
gal
m/s
ft/s
pt
RANGE
COUNT
.