F u n c .
N a m e
C o d e
P038
Torque bias polarity selection
P039
Speed limit of Torque control
(Forward rotation)
Speed limit of Torque control
P040
(Reverse rotation)
P041
Speed / Torque control
switching time
Communication watchdog
P044
timer
(for option)
Inverter action on
P045
communication error
(for option)
DeviceNet polled I/O:
P046
Output instance number
Inverter action on
P048
communication idle mode
P049
Motor poles setting for RPM
P055
Pulse train input frequency
scale setting
Pulse train input frequency
P056
filter time constant setting
Pulse train input bias setting
P057
P058
Limitation of the pulse train
input setting
Lower cut off level of the
P059
input pulse
P060
Multistage position 0
P061
Multistage position 1
P062
Multistage position 2
P063
Multistage position 3
P064
Multistage position 4
P065
Multistage position 5
P066
Multistage position 6
P067
Multistage position 7
Homing mode selection
P068
Homing direction
P069
" P " F u n c t i o n
D e s c r i p t i o n
Two option codes:
00...According to the sign
01...According to the rotation
direction
Set range is 0.00~120.00Hz.
Set range is 0.00~120.00Hz.
Set range is 0 to 1000 ms.
Set range is 0.00 to 99.99s.
00...(tripping),
01...(tripping after decelerating and
stopping the motor),
02...(ignoring errors),
03...(stopping the motor after
free-running),
04...(decelerating and stopping the
motor)
00 to 20
00...(tripping),
01...(tripping after decelerating and
stopping the motor),
02...(ignoring errors),
03...(stopping the motor after
free-running),
04...(decelerating and stopping the
motor)
0/2/4/6/8/10/12/14/16/18/20/22/24/
26/28/30/32/34/36/38/40/42/44/46/48
Sets the pulse numbers at max.
frequency, set range is 1.0~32.0 kHz
Set range is 0.01~2.00 s.
Set range is –100~100 %
Set range is 0~100 %
0.01 to 20.00[%]
P073 to P072
(Displayed higher 4-digits only)
00...Low speed mode
01...High speed mode
00...Forward rotation side
01...Reverse rotation side
85
R u n
D e f a u l ts
M o d e
I n i t i a l
Units
E d i t
d a ta
00
0.00
Hz
0.00
Hz
0.
ms
1.00
00
1
00
0
Pole
*
25.0
1
kHz
*
0.10
1
s.
*
0.
1
%
*
100.
1
%
*
1.00
1
%
0
Pulse
0
Pulse
0
Pulse
0
Pulse
0
Pulse
0
Pulse
0
Pulse
0
Pulse
00
01
-
s
-
-
-
-
-

Advertisement