Input Function Summary Table – This table shows all functions for intelligent input at a glance.
Detailed description of these functions, related parameters and settings, and example wiring
diagrams are in "Using Intelligent Input Terminals" on page 27.
Option
Terminal
Code
Symbol
00
FW
01
RV
02
CF1
03
CF2
04
CF3
05
CF4
06
JG
07
DB
08
SET
09
2CH
11
FRS
12
EXT
13
USP
14
CS
15
SFT
16
AT
18
RS
19
PTC
Input Function Summary Table
Function Name
FORWARD Run/Stop
Reverse Run/Stop
Multi-speed Select,
Bit 0 (LSB)
Multi-speed Select,
Bit 1
Multi-speed Select,
Bit 2
Multi-speed Select,
Bit 3 (MSB)
Jogging
External DC braking
Set (select) 2nd Motor
Data
2-stage Acceleration
and Deceleration
Free-run Stop
External Trip
Unattended Start
Protection
Commercial power
source switchover
Software Lock
Analog Input
Voltage/Current Select
Reset Inverter
PTC thermistor
Thermal Protection
(C005 only)
ON
Inverter is in Run Mode, motor runs forward
OFF
Inverter is in Stop Mode, motor stops
ON
Inverter is in Run Mode, motor runs reverse
OFF
Inverter is in Stop Mode, motor stops
ON
Binary encoded speed select, Bit 0, logical 1
OFF
Binary encoded speed select, Bit 0, logical 0
ON
Binary encoded speed select, Bit 1, logical 1
OFF
Binary encoded speed select, Bit 1, logical 0
ON
Binary encoded speed select, Bit 2, logical 1
OFF
Binary encoded speed select, Bit 2, logical 0
ON
Binary encoded speed select, Bit 3, logical 1
OFF
Binary encoded speed select, Bit 3, logical 0
Inverter is in Run Mode, output to motor runs at jog
ON
parameter frequency
OFF
Inverter is in Stop Mode
DC braking will be applied
ON
during deceleration
OFF
DC braking will not be applied
The inverter uses 2nd motor
ON
parameters for generating frequency
output to motor
The inverter uses 1st (main) motor parameters for
OFF
generating frequency output to motor
Frequency output uses 2nd-stage acceleration and
ON
deceleration values
Frequency output uses standard acceleration and
OFF
deceleration values
Causes output to turn OFF, allowing motor to free run
ON
(coast) to stop
Output operates normally, so controlled deceleration
OFF
stop motor
When assigned input transitions OFF to ON, inverter
ON
latches trip event and displays
No trip event for ON to OFF, any recorded trip events
OFF
remain in history until reset
On powerup, the inverter will not resume a Run
ON
command (mostly used in the US)
On powerup, the inverter will resume a Run command
OFF
that was active before power loss
ON
Motor can be driven by commercial power
OFF
Motor is driven via the inverter
The keypad and remote programming devices are
ON
prevented from changing parameters
OFF
The parameters may be edited and stored
ON
Refer to "Analog Input Operation" on page 41.
OFF
The trip condition is reset, the motor output is turned
ON
OFF, and powerup reset is asserted
OFF
Normal power-ON operation
When a thermistor is connected to terminal [5] and [L],
ANLG
the inverter checks for over-temperature and will cause
trip event and turn OFF output to motor
74
Description
E 12