I Preparation - Panasonic BM-ET200 Operating Instructions Manual

Iris reader
Hide thumbs Also See for BM-ET200:
Table of Contents

Advertisement

G
Description about the Connection Example
• When the power supply is shut down, an alarm signal is supplied from the alarm output 1 (power status) to alarm devices.
• When the front cover is removed from an iris reader or the iris reader is removed from the wall, an alarm signal is sent from
the alarm output 2 (tamper detection) to alarm devices.
• When recognition is not successfully completed, an alarm signal is sent from the recognition result output 2 (REJECT) to a
digital disk recorder. Then, the digital disk recorder automatically records the images output from the option camera.

I Preparation

Prepare the following items before the installation. The necessary items and their lengths differ depending on situation.
G
Preparing the Necessary Items
Item
Power cable (Mandatory)
Coaxial cable
LAN cable
Cable for the alarm and
trigger terminals
Cable for the Wiegand
terminals
Cable for the RS-485 ter-
minals
Audio output cable
Cable for numeric key
24
Item number/Recommended type
UL style 1015 (AWG 14-15) or equivalents
Maximum distance: 5 m {16.4 ft.}
UL Listed NEC type CM or CL2, RG-6/U
type
Recommended distance: 20 m {65.6 ft.} or
less
UL style 1666, CSA-FT4 or equivalents
10 Base-T/100 Base-TX (Category 5)*
UL style 1571 or equivalents, AWG 22 - 16
Shielded cable or shielded wire must be
used.
UL style 1571 or equivalents, AWG 22 - 16
Shielded cable or shielded wire must be
used.
UL style 1571 or equivalents, AWG 22 - 16
Shielded cable or shielded wire must be
used.
ø3.5 mm stereo mini plug
USB cable/Series A
Recommended cable length: 3 m {9.8 ft.}
or less
Necessary when supplying power from the exter-
nal power-supply device to the iris reader
Solder both ends of the cable with M3 screw
clamp terminals.
For connection between an external video-input
device and the iris reader
Connect both ends with BNC plugs.
Necessary for communication between the iris
1
readers and iris server (or setup PC)
Remove 9 mm - 10 mm of the outer jacket of the
cable and twist the cable core to prevent the short
circuit first.
Recommended tool: Flat-blade screwdriver
(ø3 mm x 2.6 mm (W) {ø0.12" x 0.1" (W)})
Remove 9 mm - 10 mm of the outer jacket of the
cable and twist the cable core to prevent the short
circuit first.
Recommended tool: Flat-blade screwdriver
(ø3 mm x 2.6 mm (W) {ø0.12" x 0.1" (W)})
Remove 9 mm - 10 mm of the outer jacket of the
cable and twist the cable core to prevent the short
circuit first.
Recommended tool: Flat-blade screwdriver
(ø3 mm x 2.6 mm (W) {ø0.12" x 0.1" (W)})
Pre-out (10 kΩ, –16 dBV)
Notes:
• Connect the cables to the stereo speakers
equipped with the audio amplifier.
• When connected to a monaural speaker, no
sound may be heard.
Necessary when using a numeric key to enter
numbers for PIN recognition, etc. (When using with
the external storage device, a USB hub is neces-
sary.)
Use

Hide quick links:

Advertisement

Table of Contents
loading