Download Print this page

Panasonic ER-X Series Manual page 8

Area ionizer
Hide thumbs Also See for ER-X Series:

Advertisement

8
ER-X
Area Ionizer
ORDER GUIDE
Controller
Please order power cable or AC adapter separately.
Type
Standard
type
Head connection cables
Appearance
Note: Cannot be used with the high and low temperature resistant type head ER-X□HC.
OPTIONS
Designation
Model No.
ER-XCC2
Power cable
ER-XCC5
ER-XAPS-EX
AC adapter
ER-XAPS
CN-ACCN-C2
AC cable
CN-ACKR-C2
ER-XANT
ER-XANT1
Discharge
ER-XANT2
needle unit
ER-XANTHC
ER-XANT2HC
Discharge part
ER-XACVR
protective cover
Notes: 1) Rating of the AC cable is 125 V AC. If the voltage used exceeds 125 V AC, prepare a proper cable
by yourself or purchase our optional cable CN-ACCN-C2 or CN-ACKR-C2. And, the AC cable is
not enclosed with ER-XAPS-EX.
2) Cannot be used with the high and low temperature resistanttype head ER-X□HC.
3) The number of set(s) you need depends on the head model No.
ER-X016 ER-X032 ER-X048 ER-X064
Model No.
No. of set
(2 pcs per set)
SERIES
Appearance
Head connection cable is not supplied with the head. Please order it separately.
Model No.
ER-XCCJ2H
Length: 2 m
ER-XCCJ5H
Length: 5 m
ER-XCCJ10H (Note)
Length: 10 m
Description
Length: 2 m
6.562 ft
Net weight: 80 g approx.
Length: 5 m
16.404 ft
Net weight: 190 g approx.
IN: 100-240 V AC, 50/60 Hz
OUT: 24 V DC, 1.5 A
Ambient temperature: 0 to +40 °C
Cable length between connector and AC adaptor: 1.8 m
Ground wire: 3.7 m
12.139 ft
AC cable: 1 pc., Cable length 1.8 m
Wiring connector terminals: 6 pcs.
AC cable (conforming to CCC), Length: 2 m
AC cable (conforming to KTL), Length: 2 m
For ER-X016/X032/X048/X064. (Note 2)
Unit with replacement tungsten needles: 1 pc.
For ER-X001.
Unit with replacement tungsten needles: 1 pc.
For ER-X008. (Note 2)
Unit with replacement tungsten needles: 1 pc.
For ER-X016HC/X032HC/X048HC/X064HC.
Unit with replacement tungsten needles: 1 pc.
For ER-X008HC.
Unit with replacement tungsten needles: 1 pc.
For ER-X016/X032/X048/X064. (Note 2)
Enables to prevent electric shock by mounting to the heads.
2 pcs. per set. (Note 3)
Material: Polycarbonate, Weight: 20 g approx. (1 set)
* No effect on charge removal capacity of the heads by mounting a
discharge part protection cover
1 set
2 sets
3 sets
Number of heads
Model No.
connected
ER-XC02
Max. 2 units
Description
6.562
ft, Net weight: 120 g approx.
16.404
ft, Net weight: 290 g approx.
32.808
ft, Net weight: 560 g approx.
0.15 mm
10-core cabtyre cable
2
with connector
Cable outer diameter: ø5.3 mm
ø0.209 in
+32 to +104 °F
5.905 ft
5.906
ft, Rating 125 V AC (Note 1)
6.562 ft
6.562 ft
4 sets
Output
PhotoMOS relay
Cabtyre cable with
both connector
Power cable
ER-XCC□
AC adapter
ER-XAPS-EX
ER-XAPS
Discharge needle unit
ER-XANT
ER-XANTHC
ER-XANT1
ER-XANT2
ER-XANT2HC
Discharge part protective cover
ER-XACVR

Advertisement

loading