ER-X
Area Ionizer
SPECIFICATIONS
Allowable ambient temperature of high and low temperature resistant type head ER-X□HC and its installation
When installing, make sure to expose a section measuring 500 mm
shown below for the protection of the high-voltage unit.
Allowable ambient temperature of the head
-60 to +200 °C
-76 to +392 °F
High-voltage cable (1.8 m
5.906
Note: The high and low temperature resistant type ER-X□HC cannot be connected with the ER-XCCJ10H head connection cable (10 m
Controller
Type
Item
Model No.
CE marking directive compliance
Number of heads connected
Supply voltage
Current consumption
Indicator
DSC (Discharge)
CHECK
ERROR
Level meter
Output
ALARM
ERROR
COM (Common)
Output operation
Short-circuit protection
Discharge control input (DSC OFF)
Contamination level
Overvoltage category
Elevation
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Enclosure grounding method
Material
Weight
Accessories
Note: Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
SERIES
Allowable ambient temperature of the high-voltage unit
0 to +50 °C
Head
500 mm
19.685 in
ft)
or more
450 mA or less when connecting 1 head, 800 mA or less when connecting 2 heads
Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected)
Green LED (5 levels, lights up depending on amount of the charge or ion generation)
PhotoMOS relay output
• Maximum load current: 100 mA
• Applied voltage: 30 V DC or less (between output-output common)
• Residual voltage: 1.5 V or less (at 100 mA load current)
ALARM: ON when dirt or wear of the discharge needle is detected, OFF when operation is normal.
ERROR: OFF when abnormal discharge is detected, ON when operation is normal.
0 to +50 °C
+32 to +122 °F
1,000 V AC for one min. between all supply terminals connected together and enclosure
500 V AC for on min. between supply terminals and F.G.
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm
100 m/s
Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex])
Ground wire (3.7 m
19.685 in
+32 to +122 °F
High-voltage unit
Head connection cable (Note)
Controller
ER-XC02
EMC Directive, RoHS Directive
Maximum 2 units
24 V DC ±10 %
Displays status of Head 1 and 2
Green LED (lights up when discharging)
Red LED (lights up when abnormal discharge is detected)
Incorporated (automatic reset type)
Discharge allowed: Open, Discharge halt: 24 V or 0 V shorted
2
I
2,000 m
6561.68 ft
or less (Note)
(No dew condensation allowed), Storage: –10 to +65 °C
35 to 65 % RH, Storage: 35 to 85 % RH
0.030 in
double amplitude in X, Y and Z directions for two hours each
2
acceleration (10 G approx.) in X, Y and Z directions three times each
Floating
Enclosure: ABS
Net weight: 130 g approx.
12.139 ft
approx.): 1 pc.
or more to the normal temperature area as
32.808 ft
+14 to +149 °F
in length).