I/O CIRCUIT AND WIRING DIAGRAMS
New-type controller
(produced from April 2014 on)
Notice: Products manufactured from April 2014 and before April 2016 cannot be used with the high and low temperature resistant type head ER-X008HC.
For the
Identification of previous-type and new-type controllers and for the combination with the
Power connector terminal arrangement
1
2
3
4
5
6
7
8
9
10
(Front view)
Housing: 5569-10A
[Manufactured by Molex]
Terminal
Terminal
Color
No.
name
code
1
0 V
Blue
2
COM(–)
Discharge
3
Pink
control input
4
COM(OUT)
Violet
5
F.G. terminal Green / Yellow
6
24 V
Brown
7
COM(+)
8
COM(IN)
White
9
Alarm output
Orange
10
Error output
Black
Note: Color code refers to cable colors
of an optional power supply
cable.
Previous-type controller
(produced before March 2014)
Notice: Products manufactured before March 2014 cannot be used with ER-X001, ER-X008 and the high and low temperature resistant type
head ER-X□HC.
For the
Identification of previous-type and new-type controllers and for the combination with the
Power connector terminal arrangement
1
2
3
4
5
6
7
8
9
10
(Front view)
Housing: 5569-10A
[Manufactured by Molex]
Terminal
Terminal
Color
No.
name
code
1
0 V
Blue
2
COM(–)
Discharge
3
Pink
control input
4
COM(OUT)
Violet
5
F.G. terminal Green / Yellow
6
24 V
Brown
7
COM(+)
8
White
9
Alarm output
Orange
10
Error output
Black
Note: Color code refers to cable colors
of an optional power supply
cable.
When connecting the output to negative common
(Brown) +V
6
COM(+)
7
(Violet) COM (OUT)
4
(Orange) Alarm output
Load
9
(Black) Error output
Load
10
(Pink) Discharge control input
3
(White) COM (IN)
8
(Blue) 0 V
1
COM(─)
2
5
Be sure to ground.
(Green/Yellow) F.G.
Internal circuit
User's circuit
*1
Non-voltage contact or
PNP open-collector transistor
or
Contact "closed" or transistor ON: Discharge halt
Contact "open" or transistor OFF: Starting discharge
Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock.
In the case of ER-X001, the head mounting bracket and F.G. terminal are internally connected.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF
(open) the discharge control input. Discharge will start in 20 ms.
When connecting the output to negative common
(Brown) +V
6
COM(+)
7
(Violet) COM (OUT)
4
(Orange) Alarm output
Load
9
(Black) Error output
Load
10
(Pink) Discharge control input
3
(Blue) 0 V
1
COM(─)
2
5
Be sure to ground.
(Green/Yellow) F.G.
Internal circuit
User's circuit
*1
Non-voltage contact or
PNP open-collector transistor
or
Contact "closed" or transistor ON: Discharge halt
Contact "open" or transistor OFF: Starting discharge
Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF
(open) the discharge control input. Discharge will start in 20 ms.
Area Ionizer
When connecting the output to positive common
(Brown) +V
6
COM(+)
7
(White) COM (IN)
*1
8
(Pink) Discharge control input
3
+
24 V DC
±10 %
(Orange) Alarm output
9
(Black) Error output
10
(Violet) COM (OUT)
4
(Blue) 0 V
1
COM(─)
2
5
(Green/Yellow) F.G.
Internal circuit
*2
Non-voltage contact or
NPN open-collector transistor
Contact "closed" or transistor ON: Discharge halt
Contact "open" or transistor OFF: Starting discharge
When connecting the output to positive common
(Brown) +V
6
COM(+)
7
*1
3
(Pink) Discharge control input
+
24 V DC
(Orange) Alarm output
±10 %
9
(Black) Error output
10
(Violet) COM (OUT)
4
(Blue) 0 V
1
COM(─)
2
5
(Green/Yellow) F.G.
Internal circuit
*2
Non-voltage contact or
NPN open-collector transistor
Contact "closed" or transistor ON: Discharge halt
Contact "open" or transistor OFF: Starting discharge
ER-X
SERIES
head, refer to p.16.
+
24 V DC
*2
±10 %
Load
Load
Be sure to ground.
User's circuit
or
head, refer to p.16.
+
24 V DC
*2
±10 %
Load
Load
Be sure to ground.
User's circuit
or
15