12.3.1 Configuration
Home -> Configuration -> Parameter
Depending on the selected sensor type, there are up to three predefined pressure and distance values that can be
selected directly, as well as two (white) fields that you can use to enter any pressure and/or distance value you want.
For the various sensor types, there are various minimum and maximum defined distances between the METPOINT
and the leak that must be maintained in order to be able to calculate valid values for the leakage loss volumetric flow
rate and the costs per year. Do not carry out measurements outside of these distance ranges!
The configuration settings can be used to
select the system of units you want and enter the parameters needed in
order to calculate annual leakage costs.
•
Select either the ISO or US system of units
•
To define the required costs for the calculation, tap the
"Cost / 1000 m³" text field There are two mode options available for
selection here:
Standard:
Cost per 1000 units of volume
Enter the cost and currency
Default value: 19 € / 1000 m³ (0.538 € / 1000 cf)
Expert:
Can be used to define the electricity cost / kWh and the system's specific
power in detail.
There are three predefined system values for the specific power, as well as
a custom input field that you can use to enter a different value.
-> Enter the operating hours per year
-> Sensor type
Select the sensor type based on the application and ambient conditions in
question; see section 8.
Select the sensor type and confirm with "OK."
METPOINT
CID
®
CID
®
23 | 56