30
Bosch Rexroth AG | Mobile Hydraulics

Verstellung demontieren

Dismantling of the control
Alt / Old
Neu / New
A4VG | RDE 92 003-02-R/03.03
Alt / Old
Neu / New
Lage vom Deckel markieren, Maß "Nullage" fest-
halten - Mutter lösen.
Mark position of the cover, note measure of
"zero position" - loosen nut.
Deckel abdrehen.
Remove cover.