Canon imageRUNNER 1750 Series Service Manual page 270

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

No.
Counter type
501 Scan (Total1)
505 Bk scan (Total1)
506 Bk scan (Total2)
507 Bk scan (L)
508 Bk scan (S)
509 C scanTotal (1)
510 C scanTotal (2)
511 C scan (L)
512 C scan (S)
915 Transmission scan total2 (C)
916 Transmission scan total2 (Bk)
917 Transmission scan total3 (C)
918 Transmission scanTotal3 (Bk)
921 Transmission scanTotal5 (C)
922 Transmission scanTotal5 (Bk)
929 Transmission scanTotal6 (C)
930 Transmission scanTotal6 (Bk)
939 Remote scan (C)
940 Remote scan (Bk)
1
945 Transmission scan/E-mail (C)
946 Transmission scan/E-mail (Bk)
● 062: Communication termination timer at SMTP transmission protocol
level
Communication termination timer at SMTP transmission protocol level can be set.
● 063: Communication termination timer at SMTP reception protocol
level
Communication termination timer at SMTP reception protocol level can be set.
8
Service Mode > Details of Service Mode > #NUMERIC > Details
Scan system
Bk
C
1-sided
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8
Service Mode > Details of Service Mode > #NUMERIC > Details
● 064: Communication termination timer at POP reception protocol
level
Communication termination timer at POP reception protocol level can be set.
● 065: Communication termination timer at FTP transmission protocol
level
Communication termination timer at FTP transmission protocol level can be set.
● 066: Communication termination timer from start to completion of the
transmission of SMTP transmission data
Communication termination timer from start to completion of the transmission of SMTP
transmission data can be set.
1
● 067: Communication termination timer from start to completion of the
reception of SMTP reception data
Communication termination timer from start to completion of the reception of SMTP reception
1
data can be set.
1
● 068: Communication termination timer from start to completion of the
1
reception of POP reception data
Communication termination timer from start to completion of the reception of POP reception
data can be set.
● 069: Communication termination timer from start to completion of the
transmission of FTP transmission data
Communication termination timer from start to completion of the transmission of FTP
transmission data can be set.
● 074: Port number of e-RDS RGW
Port number of e-RDS RGW can be set.
T-8-30
1 to 65535
Default: 443
● 075: Transmission intervals for e-RDS 3rd party
Transmission intervals for e-RDS 3rd party can be set.
1 to 168 (hours)
Default: 24
8-21