Canon imageRUNNER 1750 Series Service Manual page 259

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

Detailed Discussions of Bit 1
For reception, the length of time during which the absence of the carrier is detected between
DCS and TCF may be set. This bit is valid when '1' is set to bit 0 of #1 SSSW SW18.
Detailed Discussions of Bit 2
You can change the parameter relating to communication control for IP network (SSSW-SW02
bit4) to the existing control in a batch process. The parameter value is handled as a fixed
value.
● SSSW-SW22
List of Functions
Bit
Function
0
To disable NSX transmission.
1
not used
2
not used
3
Prohibit manual polling
4
not used
5
not used
6
not used
7
not used
Detailed Discussions of Bit 0
Nonstandard protocol (own company mode) can be disabled.
Detailed Discussions of Bit 3
Selects whether to prohibit by manual polling (off hook key + start key).
● SSSW-SW25
List of Functions
Bit
Function
Transmission telephone numbers displayed on reports from
0
CSI
1
not used
2
If void CSI has been received, handle as non-received CSI.Yes
3
Menu display of message language
4
not used
5
not used
6
not used
7
not used
8
Service Mode > Details of Service Mode > #SSSW > Details
1
0
Yes
No
-
-
-
-
Yes
No
-
-
-
-
-
-
-
-
T-8-17
1
0
Other fax
Called number
number
-
-
No
Display
Do not display
-
-
-
-
-
-
-
-
T-8-18
8
Service Mode > Details of Service Mode > #SSSW > Details
Detailed Discussions of Bit 0
Selects the transmission telephone number displayed on reports after the completion of
transmission.
When "Called number" is selected, the telephone number the fax called is displayed on
reports.
When "Other fax number" is selected, the telephone number sent from the other fax (the CSI
signal data) is displayed on reports.
Detailed Discussions of Bit 2
At "1" on this Bit, ignore the void CSI if received and if the dial has been made at this point,
the dialed number will be indicated on the LCD/ Report screen.
At "0" on this Bit, even though the dialed number is acknowledged, LCD/Report screen will
indicate nothing.
Detailed Discussions of Bit 3
When "Display" is selected, adds a Message Language menu to the user data "System
Setting". This allows selecting different languages which to show displays and reports.
● SSSW-SW28
List of Functions
Bit
Function
0
Caller V.8 protocol
1
Called party V.8 protocol
2
Caller V.8 protocol late start
3
Called party V.8 protocol late start
4
V.34 reception fallback
5
V.34 transmission fallback
6
not used
7
not used
Detailed Discussions of Bit 0
Select whether to use the V.8 protocol when calling. If NO is selected, the V.8 protocol is
inhibited at calling and the V.21 protocol is used
Detailed Discussions of Bit 1
Select whether to use the V.8 protocol when called. If NO is selected, the V8 protocol is
inhibited when called and the V.21 protocol is used.
8-10
1
0
No
Yes
No
Yes
No
Yes
No
Yes
Prohibited
Not prohibited
Prohibited
Not prohibited
-
-
-
-
T-8-19
8-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner 1740 seriesImagerunner 1730 series

Table of Contents