Technical data
– Pulse frequency, for example 4/8/16 kHz and multiples thereof, assessed up
to a maximum of 100 kHz
5. The routing of power cables has a significant impact on the electromagnetic
fields that occur.
Install and operate the components inside metallic cabinets in compliance
with the documentation and use shielded motor cables.
Description
The following information regarding electromagnetic fields relates solely to
converters supplied by Siemens.
The converters are normally used in machines. The assessment and testing is
based on DIN EN 12198.
The indicated minimum distances apply to the head and complete torso of the
human body.
Shorter distances are possible for extremities.
Minimum distances to the converter
Individuals without active implants
Control cabinet
closed
0 cm
SINAMICS V50 converter
89
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Control cabinet
open
Forearm length
(ap- prox. 35 cm)
Individuals with active implants
Control cabinet
closed
Must be separately assessed depending
on the active implant.
Control cabinet
open