Siemens SINAMICS V50 Operating Instructions Manual page 44

Advertisement

Parameter description
6.6 Input terminals
Code
Description
Terminal
F6.00
Command
mode
X1 terminal
F6.01
function
selection
X2 terminal
F6.02
function
selection
X3 terminal
F6.03
function
selection
X4 terminal
F6.04
function
selection
X5 terminal
F6.05
function
selection
©X6 terminal
function
selection
F6.06
©AI1 terminal
function
selection
©X7 terminal
function
selection
F6.07
©AI2 terminal
function
selection
©Reserve
®X8 terminal
F6.08
function
selection
©AI1 terminal
F6.09
function
selection
SINAMICS V50 converter
43
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
0: Two-wire mode 1
1: Two-wire mode 2
2: Three-wire mode 1
3: Three-wire mode 2
0: NULL
1: FWD
2: REV
3: RUN
4: F/R direction
5: HLD self-hold
6: FWD jog run
(FJOG)
7: REV jog run
(RJOG)
8: RESET
9: Freq. source
switching
10: Terminal UP
11: Terminal DOWN
12: UP/DOWN setup
clear
13: Coast to stop
14: DC brake
15: Acc./Dec. prohibit
16: Drive running
prohibit
17: Multi-step
terminal 1
18: Multi-step
terminal 2
19: Multi-step
terminal 3
20: Multi-step
terminal 4
21: Torque control
disable
22: Acc./Dec. time
selector 1
23: Acc./Dec. time
selector 2
Default
Modify
0
X
1
X
2
X
8
X
17
X
18
X
0
X
0
X
Reserved
X
Reserved
X
Modbus
Address
0700H
0701H
0702H
0703H
0704H
0705H
0706H
0707H
0708H
0709H