Strobe Test; Fire Siren Test; Communication / Reporting; Call/Answer Ras - Bosch Solution 6000 User Manual

Hide thumbs Also See for Solution 6000:
Table of Contents

Advertisement

The keypad will display the following during the
internal siren test.
Internal Audible Testing
Press any key to abort
Press OK or MENU
When the test is complete, the keypad will display
the following:
Testing Complete. Press
OK to continue
Press OK or MENU
3. Press [OK] to exit.
Outputs > Output Testing >

Strobe Test

This menu allows you to test the external strobe light.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [4] + [9] + [2].
If the system has multiple areas, the keypad will
display a list of areas.
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press

2. Use the [] and [] keys to select the area that
you want to test the strobe in, then press [OK].
Alternatively, you can enter the area number, then
press [OK].
The keypad will display the following during the
strobe test.
Strobe Activated. Will
Reset on exit
Press OK or MENU
Check and verify that the strobe light is on.
3. Press [OK] to exit.
Outputs > Output Testing >

Fire Siren Test

This menu allows you to test any sirens programmed as fire
which have been connected by your installer. The test will
last for 5 seconds.
Enter programming mode (PIN + MENU) then,
Bosch Security Systems 12/14 BLCC610U
MENU 4-9-2
OK or MENU
MENU 4-9-3
1. Enter [MENU] + [4] + [9] + [3].
If the system has multiple areas, the keypad will
display a list of areas.
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press

2. Use the [] and [] keys to select the area that
you want to test the fire sirens in, then press [OK].
Alternatively, you can enter the area number, then
press [OK].
The keypad will display the following during the fire
siren test.
Fire Audible Testing
Press any key to abort
Press OK or MENU
When the test is complete, the keypad will display
the following:
Testing Complete. Press
OK to continue
Press OK or MENU
3. Press [OK] to exit.

Communication / Reporting

Programming options in this section relate to how you
alarm system will communicate alarm information.
Your installer will advise you on the exact makeup and
configuration of your system.
Comms > Commands >

Call/Answer RAS

This menu allows you to initiate a modem call to the
installer's off-site computer for programming changes or
updates. Your installer may request that you enter this
command so that they can remotely service and configure
your system. You should not enter this command unless
requested to do so.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [0] + [1].
Comms > Commands >

Call Forward On/Off

This menu allows you to turn on and off the call forward
feature. When you turn on call forwarding, the control
panel will automatically activate and de-activate the call
forward on and call forward off sequence accordingly
when you turn Area 1 All On and off (arm and disarm).
Solution 6000
User Guide
OK or MENU
MENU 5-0-1
MENU 5-0-2
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents