Replacing a Fuse-Block
Fuse
The fuse block is in the control arm.
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Open the 2 latches that secure control-arm cove
to the control arm, and remove the cover
87).
Figure 87
1. Control-arm cover
3.
Replace the open fuse
fuse type and amperage rating.
Figure 88
1. Fuse block
40).
(Figure
g375760
2. Latch
(Figure
88) with the same
g375761
2. Fuse decal (inside the
control-arm cover)
4.
Assemble the control-arm cover to the control
arm, and secure the cover with the 2 latches.
Replacing the Telematic
Fuse
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Unlatch and tilt seat; refer to
(page
41).
3.
Remove the cap from the in-line fuse holder
labeled 10 A F
1. Cap
2. Fuse
4.
Remove the fuse from the fuse holder.
5.
Insert a fuse of the same type and amperage.
6.
Assemble the cap onto the in-line fuse holder.
7.
Lower and latch the seat; refer to