Appendices; Ul Requirements - Bosch AMC2 Installation Manual

Enclosure with 1 din rail
Hide thumbs Also See for AMC2:
Table of Contents

Advertisement

18
en | Appendices
4

Appendices

4.1

UL requirements

Notice!
i
All cables connected to the AMC2 modules and the power
supply are classified as Class 2 conductors. The battery cable
and the AC input cable are non-power limited circuits.
Notice!
Maintain a minimum of 6.4 mm spacing between all class 2 or 3
i
conductors and all electric, light, power, Class 1 conductors,
non-Class 2 or 3 signaling conductors, or medium-power
network-powered broadband communications-circuit
conductors (Figure 3.1, position 1 and 2).
Notice!
i
When the fuse (5A) of cable B (power supply battery) is blown,
replace it with a UL listed fuse and reseal the fuse holder with a
heat shrink tube.
Notice!
i
If the system is to be UL294 compliant, make sure that all the
cables and the respective parts are UL listed or approved.
Access Control Performance Levels UL 294
Line Security
2021-03 | V06 | F.01U.330.018
Destructive
Attack
I
AMC2 enclosure with 1 DIN rail
Endurance
I
Standby
Power
IV
Bosch Security Systems B.V.
II

Advertisement