■ PANEL DUCT
Detaching the PANEL DUCT
Follow the instruction below to detach the PANEL DUCT
1) Disconnect the cable from the PWB assembly SENSOR before detaching the PANEL DUCT.
Otherwise, the parts of the PWB assembly SENSOR could be scratched when detaching the
PANEL DUCT, and be damaged.
2) Unclasp the claws of the PANEL DUCT in numerical order from 1 to 6. Use a tool like a screwdriver
to easily unhook the 6th claw.
3) Move the PANEL DUCT to the direction of the arrow in the picture to separate the PANEL DUCT.
1
2
Attaching the PANEL DUCT
1) Make sure that the PWB assembly SENSOR is set in place.
Do not connect the cable to the PWB assembly SENSOR before attaching the PANEL DUCT.
2) Put the PANEL DUCT on the BOTTOM CASE, and fit the boss of the BOTTOM CASE to the
hole at around the center of the PANEL DUCT.
Make sure that the PWB assembly SENSOR is not stressed.
3) Lock the PANEL DUCT to the BOTTOM CASE with eight claws. Confirm that all of the claws
catch the PANEL DUCT firmly.
CP-X2520 ( M2-25ED ) / CP-X3020 ( M2-30ED )
3
4
Insert a tool such as a
screwdriver here to
unhook the PANEL DUCT.
Screwdriver
5
6
CAUTION
TO DISCONNECT THIS CABLE
BEFORE SEPARATING THE
PANEL DUCT.
CAUTION
CAUTION
47
Claw
Cable
MAKE SURE