Main Code 96; Main Code B3 - Sony PWS-4400 (SY) Service Manual

Multi port av storage unit
Hide thumbs Also See for PWS-4400 (SY):
Table of Contents

Advertisement

2-2-3.

Main Code 96

When an internal calendar clock error is detected, the following error occurs.
Main
Sub code
Sub code
code
(1)
(2)
96
01
00
2-2-4.

Main Code B3

Note
If main error code "B3" occurs each time the unit is turned on, contact your local Sony Sales Office/Service Center.
When a trouble was detected in the device initialization process, one of the following errors occurs.
Main
Sub code
Sub code
code
(1)
(2)
B3
01
00
B3
02
00
B3
03
00
B3
04
00
B3
11
00
B3
12
00
B3
13
00
B3
14
00
B3
28
00
PWS-4400
Error message
Description
CALENDAR CLOCK
An internal calendar clock error was detected.
ERROR
Error message
Description
SY CPLD2 INITIAL ER-
Initialization error of CPLD2 on SY-422A board was
ROR
detected.
SY FPGA1 INITIAL ER-
Initialization error of FPGA1 on SY-422A board was
ROR
detected.
SY FPGA2 INITIAL ER-
Initialization error of FPGA2 on SY-422A board was
ROR
detected. (Support in the future)
SY FPGA NOT LATEST
FPGA on the SY-422A board was not initialized by
latest data, and it was initialized by backup data.
CP CPLD2 INITIAL ER-
Initialization error of CPLD2 on CP-407A board was
ROR
detected.
CP FPGA1 INITIAL ER-
Initialization error of FPGA1 on CP-407A board was
ROR
detected.
CP BANK INITIAL ER-
Initialization error of BANK1 block in FPGA1 on
ROR
CP-407A board was detected.
CP FPGA NOT LATEST
FPGA on the CP-407A board was not initialized by lat-
est data, and it was initialized by backup data.
HP CPLD2 INITIAL ER-
Initialization error of CPLD2 on HP-160A board was
ROR
detected.
Probable cause 1: IC110 or BT101 (lithium bat-
tery) on SY-422A board
Probable cause 2: IC1 (SYS1 CPU) on SY-422A
board
Protected operation: None
Probable cause: IC1701 on SY-422A board
Protected operation: None
Probable cause: IC3 on SY-422A board
Protected operation: None
Protected operation: None
Probable cause: IC1701 on SY-422A board
Protected operation: None
Probable cause: IC2801 on CP-407A board
Protected operation: None
Probable cause 1: IC2001 on CP-407A board
Probable cause 2: SYS1
Protected operation: None
Probable cause 1: IC2001 on CP-407A board
Probable cause 2: SYS1
Protected operation: None
Probable cause 1: IC2801 on CP-407A board
Probable cause 2: SYS1
Protected operation: None
Probable cause: IC11 on HP-160A board
Protected operation: None
Continued
2-4