5-6. Registering the Scene File

5-6. Registering the Scene File
The scene file is used for storing temporary video adjustment values according to the scene. 5 files can be
stored and the data will be stored in the camera. The data can be stored using a setting menu or the
Remote Control Panel of MSU-700, etc.
Items which can be stored are indicated with
Items. For items indicated with -, their values cannot be changed by storing or calling.
n
Scene files are files for storing the differences from the reference file. Therefore when the reference file is
changed, outputs by the scene file can also be changed.
Storing Using Setting Menus
(1) Set the setting menus as follows.
[PAINT] → [SCENE|FILE] → [STANDARD]
(2) Change the scene file item to the desired value.
(3) Set the setting menus as follows.
[PAINT] → [SCENE|FILE] → [FILE|STORE]
Select the scene file number to be stored.
Calling Using Setting Menus and Clearing the Call
Select the scene file number called at the "SCENE FILE" page of the PAINT menu. Files currently being
called with be displayed with "* " at the side of the number. Selecting the number again clears the call
and resets the state before calling.
Storing with the Remote Control Panel
(1) Change the scene file item to the desired value.
(2) Press "STORE" of the scene file, and press the STORE number.
Calling with the Remote Control Panel and Clearing the Call
Press the No. switch of the "SCENE FILE" to call. The switch also lights up. Press again to cancels the
call and turns off the switch.
5-8