Combining the time of 8 seconds in location 470 with the time of 112 seconds specified in
location 471 will give a total exit time of 120 seconds.
VI. Set Stay Mode 1
Stay Mode 1 can be used to have the system partially armed with some zones isolated,
whilst others remain active. This is ideal if you still want some zones armed whilst you are
at home, especially at night when you are sleeping, e.g., doors, windows, bottom storey,
back rooms, shed, garage — zones unlikely to be entered by household members.
You can specify which zones are to be isolated in Stay Mode 1 by selecting the option
"Isolated in Stay Mode 1" in Zone Options 2 for the required zone. Each zone stores its
Zone Options 2 information at a unique location.
These are the locations for Zone Options 2 for each zone:
•
Zone 1 = 271
•
Zone 2 = 278
•
Zone 3 = 285
•
Zone 4 = 292
•
Zone 5 = 299
•
Zone 6 = 306
•
Zone 7 = 313
•
Zone 8 = 320
To select a zone for isolation in Stay Mode 1, you must enter a 15 at its location for Zone
Options 2.
For example, to have Zone 5 isolated in Stay Mode 1:
1. Enter programming mode:
2. Go to the location of Zone Options 2 for Zone 5:
3. Change the 14 to a 15:
4. Save and exit:
You can arm the alarm system in Stay Mode 1 by either holding down the [ * STAY ]
button for three seconds, or by entering your user code and pressing [ * STAY ], e.g.,
2 5 8 0
*
]. The isolated zones will flash on the keypad and the Stay (person inside
house) indicator will display.
VII. Change Installer Code
Each number of the installer code is stored in its own location. There are four locations:
[
1 2 3 4
[ 1 5 * ]
[ 9 6 0 # ]
•
Zone 9 = 327
•
Zone 10 = 334
•
Zone 11 = 341
•
Zone 12 = 348
•
Zone 13 = 355
•
Zone 14 = 362
•
Zone 15 = 369
•
Zone 16 = 376
# ]
[ 2 9 9 # ]