Download Print this page

Bosch Solution 2000 Programming page 4

With the icon keypad
Hide thumbs Also See for Solution 2000:

Advertisement

— Assign this to zones that you do not intend to use, so that they
Not Used
are removed from the system.
Each zone has a unique location that specifies its zone type. In order to select one of
the above zone types for a specific zone, you will need to enter its corresponding
number into the zone type location for that zone:
• 0 = Instant
• 1 = Handover
• 2 = Delay-1
• 9 = 24hr Tamper
• 15 = Not Used
These are the locations for the zone types for all zones (including default zone types):

(default = 2 — Delay-1)
Zone 1 = 267
(default = 1 — Handover)
Zone 2 = 274
(default = 1 — Handover)
Zone 3 = 281
(default = 1 — Handover)
Zone 4 = 288
(default = 0 — Instant)
Zone 5 = 295
(default = 0 — Instant)
Zone 6 = 302
(default = 0 — Instant)
Zone 7 = 309
(default = 9 — 24-Hour Tamper)
Zone 8 = 316
(default = 15 — Not Used)
Zone 9 = 323
(default = 15 — Not Used)
Zone 10 = 330
(default = 15 — Not Used)
Zone 11 = 337
(default = 15 — Not Used)
Zone 12 = 344
(default = 15 — Not Used)
Zone 13 = 351
(default = 15 — Not Used)
Zone 14 = 358
(default = 15 — Not Used)
Zone 15 = 365
(default = 15 — Not Used)
Zone 16 = 372
The following example will show you how to set up a standard system with Zone 1 as an
entry delay, Zone 2 as a "handover", Zone 3 as an "instant", Zones 4 - 8 as "not used",
and Zone 16 as your tampers (Solution 3000):
1. Enter the text menu:
2. Enter address program:
3. By default, Zone 1 is already set as Delay-1, so we can leave it.
4. By default, Zone 2 is already set as a Handover, so we can leave it.
[
1 2 3 4
# ]
[ 8 1 ]
Page !4 of !12