Craftsman G10-0R7G-2SB Manual page 68

Table of Contents

Advertisement

F1.05
The frequency changing method during the running and starting of the inverter.
0:Linear
Output frequency according to the linear increasing or decreasing
1:S Curve
Output frequency according to the S Curve increasing or decreasing.S curve commonly
used in the up,stop process requires quite gentle,such as The elevator,conveyor belt.
Code
F1.06
0:Deceleration to stop
When the stop command takes effect,frequency converter according to the definition of
deceleration mode and the deceleration time to reduce the output frequency,frequency
drop to 0 after downtime
1:Coast to stop
When the stop command takes effect, the inverter blocks the output immediately.The
motor coasts to stop by its mechanical inertia.
Code
F1.07
F1.08
F1.09
Acceleration/Deceleration mode
Name
Stop mode
Name
DC braking initial frequency
DC braking waiting time
DC braking current
68
0ÿ^10 00
Setting Range
0ÿ^10 00
Setting Range
0.00ÿ^F0.07
0 0.00Hz0
0.0ÿ^50.0S0 0.0S0
G:0.0ÿ^100.0%
P:0.0~80.0%
0 0.0%0